Test Name
Factor V Leiden Mutation (FVL)
Alternate DescriptionFactor V Leiden (G1691A Mutation) Activated protein C resistance; APC resistance; Factor V R506Q
LIS CodeFVL
Availability24 hours a day
Lab Section
Molecular Diagnostics Lab
Fluid TypeWhole Blood
Specimen Tube Type Transport
EDTA Lavender Top Tube
Container Whole Blood Required3.0 mls of whole blood in a EDTA Lavender Top tube
Critical ValueNot applicable
Summary Test NameFactor V Leiden Mutation
Container MicrobiologyNot applicable
Transport TimeDeliver to lab within 2 hours of specimen collection
Special Handling InstructionsDo not centrifuge
Specimen Preparation OutreachDo not spin. Keep at room temperature until courier pickup
Specimen StabilityStable for five (5) days refrigerated
Minimum Volume500ul (0.5 ml)
Specimen TransportRoom Temperature, then refrigerate
Specimen Preparation In HouseDo not spin. Transport at room temperature, then Refrigerate
Stat AvailabilityNo STAT Testing Availability
Test Turnaround Time Routines And Stats7 days
Patient PreparationNone required
Reference ValueAccompanies report
Test ResultsNegative or Positive for FVL (G1691A) Mutation
Additional Test InformationRequires Hematology / Oncology Consult